Step 03.19 — Dress the bed leads above the deck¶
Step 19 of 20 · Chapter 03 — Build plate
Parts: none.
Do:
- Lay the three leads toward the left bed extrusion's rear half, generous slack at the plate end.
- Keep them out of the round hole and the notch, and off every thumb nut.
Check
Slack loop at the plate; no lead under tension, through the deck or touching a cut edge; the thermal fuse's legs undisturbed. Nothing tied down.
What you're looking at
The plate's three leads, loose above the deck. Nothing is terminated in this chapter. They end at the bed WAGO breakout Ch 09 fits on the left bed extrusion; Ch 10 terminates them.
Caution
Rev D+ / LDO: do not zip-tie or terminate anything yet. The bed harness is a breakout design specifically so the plate can be removed from the top of the deck panel later. The bed WAGO mount is Ch 09; the terminations, the extension leads and the Omron SSR are Ch 10. src
Source: Voron manual p.60 · LDO wiki build-plate mapping · LDO wiring guide § Wiring the Bed Heater