Step 07.35 — Fit the probe and its retainer bracket¶
Step 35 of 39 · Chapter 07 — A/B belts and tensioning
Tap to enlarge
Parts:
- Omron TL-Q5MC inductive probe ×1 · Cable Kit 2.4-350 box
- the probe retainer bracket · already on the bench
- M3×30 SHCS ×2 · Fasteners, Tools & Misc box
Do: Hold the probe on the carriage face, lead up. Pass the two M3×30 SHCS through its mounting holes and the carriage into the retainer bracket's inserts behind. Snug enough to hold the probe but still let it slide.
Check
The probe is held square, parallel to the carriage face, and can still be pushed up and down with firm finger pressure.
What you're looking at
The retainer bracket is the small printed bar with two heat-set inserts that sits behind the carriage. The two M3×30 clamp the probe block to the carriage face through it. Snug only: the probe still slides for the next step.
Source: Voron manual p.143