Step 11.40 — Connect the filter fan¶
Step 41 of 67 with a helper · Chapter 11 — Skirts, panels, Clicky-Clack door, filtration
(no image — see LDO wiring guide § Connecting the Fans and the LED Strip)
Parts:
- the kit's FILTER FAN extension lead · already on the bench
Do: Mate the Nevermore's pigtail with the FILTER FAN extension and follow it back to the Leviathan. It lands on FAN3 / PF9. With the machine still unplugged, confirm that header's voltage-selection jumper is set for 24 V.
Check
Filter fan on FAN3/PF9; 24 V jumper confirmed; the lead is routed in the duct and cannot be caught by the bed or the gantry.
Helper Finds the FILTER FAN tag on the coiled lead and reads it aloud.
What you're looking at
The FILTER FAN extension is the kit lead already run to FAN3 in Ch 10 Step 10.48 and left coiled at the rear of the chamber. This step mates the Nevermore's pigtail to it. The Nevermore guide names an Octopus pin; this machine's port is FAN3 / PF9.
Caution
Rev D+ / LDO: the Nevermore guide was written for a BTT Octopus and tells you to use "Octopus Fan3 - Pinout PD13". This machine has a Leviathan. Use FAN3 / PF9 from the Rev D wiring guide's fan table. src
Source: LDO wiring guide § Connecting the fans and the LED strip · Video: Extras! @2:48:31