Skip to content
Ch 1229 / 37

Step 12.29 — Probe: Omron active, Klicky written but commented

Step 29 of 37 · Chapter 12 — Software: Pi OS image, Klipper/Moonraker/Mainsail, firmware, printer.cfg

(no image — see text)

Parts: none.

Do: The kit ships both probes. Build stock: Omron inductive for QGL only, LDO nozzle probe for Z0, Klicky parts bagged. Replace the [probe] section with the following, which keeps LDO's live values and parks a Klicky block beside them:

[probe]
##  Inductive Probe (Omron) — ACTIVE
##  Connected to PROBE on the Nitehawk-SB V2 (the Leviathan's Z-PROBE header stays empty)
##  This probe is not used for Z height, only Quad Gantry Leveling
pin: nhk:PC15
x_offset: 0
y_offset: 25.0
z_offset: 0
speed: 10.0
samples: 3
samples_result: median
sample_retract_dist: 3.0
samples_tolerance: 0.006
samples_tolerance_retries: 3

##  ---- Klicky alternative — NOT ACTIVE ----------------------------------
##  Comment out the [probe] block above before uncommenting this one.
##  Klicky also needs the klicky-probe macro set, a printed dock, and its own
##  attach/dock sequence inside QUAD_GANTRY_LEVEL. On the toolhead PCB the
##  Klicky cable goes to the same PROBE port, but the 24V pin is not connected.
##  Confirm the sense of the switch with QUERY_PROBE before ANY Z move: if it
##  reports TRIGGERED with the probe off the dock, add a leading "!" to the pin.
#[probe]
#pin: ^nhk:PC15             # (verify on bench) — microswitch needs a pull-up
#x_offset: 0                # (verify on bench) — depends on your dock/mount
#y_offset: 19.75            # (verify on bench) — klicky default, measure yours
#z_offset: 6.42             # (verify on bench) — set by PROBE_CALIBRATE
#speed: 10.0
#samples: 3
#samples_result: median
#sample_retract_dist: 3.0
#samples_tolerance: 0.006
#samples_tolerance_retries: 3

check Check

exactly one live [probe] section. grep -c '^\[probe\]' printer.cfg returns 1.

What you're looking at

A [probe] section describes what the machine uses to measure bed height. This kit has two: the Omron inductive probe, for gantry levelling only, and the Klicky dockable microswitch. Klipper allows exactly one live [probe], so the unused one is parked as commented text.

Caution

Rev D+ / LDO: the PROBE port on the Nitehawk-SB V2 is JST-PH2.0, not the JST-XH2.5 the wiring guide describes; a pigtail crimped to XH2.5 will not fit (survey §4.1 ③). The fibreglass tape goes on the front and sides of the Omron only, never the back or bottom, or it will not sense. src · src

Source: leviathan-printer-rev-d-sbv2.cfg · Klipper docs § probe · Nitehawk-SB V2 doc § Port and pin definitions · Video: More Extras! @3:24:00 (differs: Euclid probe (Klicky fitted later, Part 11); this kit uses the Omron inductive probe + LDO nozzle probe, Klicky bagged)