Step 13.11 — Bay fan and filter fan

Step 11 of 54 · Chapter 13 — Initial startup

(no image — see text)

Parts: none.

Do:

  1. Set the Bed target to 60; the bay fan pair starts within a second.
  2. Set the bed back to Off; the pair keeps running about 30 s, then stops.
  3. Send SET_FAN_SPEED FAN=nevermore SPEED=1, confirm it runs, then SET_FAN_SPEED FAN=nevermore SPEED=0.

check Check

The bay fan pair starts the instant a bed target is set and runs on 30 s after Off; the Nevermore runs only when commanded.

What you're looking at

Two fans that are not on the toolhead: the 6020 pair in the electronics bay, tied to the bed heater being commanded and to any enabled stepper, and the Nevermore blower, which Ch 12 made a macro-commandable fan rather than a heater-slaved one.

Caution

Rev D+ / LDO: the LDO config names FAN3/PF9 [heater_fan exhaust_fan], but that port drives the Nevermore filter fan; the kit has no exhaust fan. Ch 12 Step 12.32 replaced it with [fan_generic nevermore], so there is no heater_temp: 60 trigger and nothing happens at bed 60 °C. (survey §3.2, §4.2 p.250–253)

tip Tip

[controller_fan controller_fan] on FAN2/PF7 keys on the heater's non-zero target or on any enabled stepper, not on temperature, and runs on for idle_timeout, 30 s by default. The Nevermore is FAN3/PF9.

Source: Voron startup wizard § Controller fan · leviathan-printer-rev-d-sbv2.cfg · Klipper controller_fan.py · LDO wiring guide § Connecting the fans and the LED strip