Step 08.47 — Hotend heater into the screw terminal¶
Step 47 of 65 · Chapter 08 — Toolhead: Stealthburner, Clockwork 2, Revo HF, Nitehawk-SB V2
Gather for this segment — steps 08.47–08.53 (~25 min)
Fasteners, Tools & Misc box
- M3×6 captive screw ×1
The LDO kit, no BOM row
- chamber thermistor, pre-terminated ×1
- grounding cable, toolboard to extruder motor ×1
- M3 screw, motor end of the grounding cable ×1
Printed parts
cw2_captive_pcb_cover.stl×1 · bin 08-CW2
Tools and consumables
- 2.5 mm slot-head screwdriver
- multimeter
Already on the bench
- the Revo heater leads
- the pancake stepper lead
- the inductive probe's pre-terminated lead
Parts:
- the Revo heater leads · already on the bench
- 2.5 mm slot-head screwdriver · tool
Do: Land the two ferruled heater leads in the HE0 screw terminal. Polarity does not matter on a resistive heater. Tighten firmly with the 2.5 mm slot-head driver and tug-test each lead.
Check
No copper visible outside the ferrule; neither lead pulls out; the two terminals cannot touch.
What you're looking at
HE0 is the heater output, the highest-current thing on this board, hence a screw terminal and not a plug. A cartridge heater is a plain resistor, so polarity is irrelevant; what matters is that no stray strand escapes the ferrule and bridges the terminals.
Source: Nitehawk-SB V2 pinout