Skip to content
Ch 0913 / 36

Step 09.13 — Build and mount the mains WAGO block

Step 13 of 36 · Chapter 09 — Electronics bay

Tap to enlarge

Parts:

  • wago_221-415_mount_3by5 ×1 · bin 09-bay
  • WAGO 221-415 (5-way) ×3 · Electronics 1 box
  • M5×10 BHCS ×2 · Fasteners, Tools & Misc box
  • M5 T-nut ×2 · Fasteners, Tools & Misc box

Do:

  1. Snap the three WAGO 221-415 clamps into the mount, levers facing outward.
  2. Slide two M5 T-nuts into the rear extrusion's inner slot, right of the inlet panel.
  3. Hook the mount on and fasten with M5×10 BHCS.

Check

All three clamps seated with no step between clamp and mount, every lever free to lift, mount solid within reach of the inlet's leads.

What you're looking at

A WAGO 221 is a lever-operated push-in connector: lift the lever, push a stripped conductor in, drop the lever, and it is clamped. These three 5-way blocks are the mains distribution nodes, one each for live, neutral and protective earth.

Caution

Rev D+ / LDO: the manual titles p.165 "ALTERNATE MAINS DISTRIBUTION — WAGO". For this kit it is not an alternate — it is the only path. The BOM ships three 221-415 clamps, and Ch 10 uses them as the L / N / PE distribution nodes. src

Caution

Rev D+ / LDO: if your printed mount has insert bosses, heat-set them in the same pass as 09.10 — (verify on bench); the stock Voron part is snap-fit only.

Good stopping point · ~30 min since the last one

Pi bracket and 5 V PSU correctly skipped, inlet panel heat-set and fitted with the IEC module, panel bolted to the rear extrusion, mains WAGO block built and mounted. Nothing is terminated and the C13 cord stays in its bag — do not connect anything to the inlet.

Source: Voron manual p.165 · LDO wiring guide § Preparing the inlet · LDO 350 Rev D BOM