Skip to content
Ch 10 › Section 4 — Above deck: probe, endstops, nozzle probe, lighting32 / 80

Step 10.32 — Repin the XY endstop cable (only if labelled X Stop / Y Stop)

Step 32 of 80 · Chapter 10 — Wiring and Checkpoint #1

Parts:

  • XY endstop cable ×1 · set out now, fitted later
  • tweezers or the supplied 2.5 mm flat screwdriver · tool

Do:

  1. On X Stop, press the position 3 retention tab down, pull the wire out, bend the tab up, and insert it at position 2.
  2. On Y Stop, move the wire from 2 to 3. Light force only.

check Check

Meter on continuity, against LDO's map:

What you're looking at

Inside a JST housing each crimped wire is held by a small springy retention tab; press the tab flat and the wire slides out, bend it back up and it locks into its new position. The photo shows that tab.

JST-XH 4P pin goes to
4 X Stop pin 2
3 X Stop pin 1
2 Y Stop pin 1
1 Y Stop pin 3

All four beep, and each repinned wire survives a light tug.

Source: LDO XY endstop reconnecting guide · LDO guide image retention_tab.jpg