Step 10.32 — Repin the XY endstop cable (only if labelled X Stop / Y Stop)¶
Step 32 of 80 · Chapter 10 — Wiring and Checkpoint #1
Parts:
- XY endstop cable ×1 · set out now, fitted later
- tweezers or the supplied 2.5 mm flat screwdriver · tool
Do:
- On X Stop, press the position 3 retention tab down, pull the wire out, bend the tab up, and insert it at position 2.
- On Y Stop, move the wire from 2 to 3. Light force only.
Check
Meter on continuity, against LDO's map:
What you're looking at
Inside a JST housing each crimped wire is held by a small springy retention tab; press the tab flat and the wire slides out, bend it back up and it locks into its new position. The photo shows that tab.
| JST-XH 4P pin | goes to |
|---|---|
| 4 | X Stop pin 2 |
| 3 | X Stop pin 1 |
| 2 | Y Stop pin 1 |
| 1 | Y Stop pin 3 |
All four beep, and each repinned wire survives a light tug.
Source: LDO XY endstop reconnecting guide · LDO guide image retention_tab.jpg