Step 14.2 — Confirm the heaters are already PID-tuned

Step 2 of 36 · Chapter 14 — Calibration and tuning

(no image — see text)

Parts: none.

Do: Both heaters were tuned and saved in Ch 13 at Step 13.29; do not repeat that here. Open printer.cfg and confirm both PID stanzas are in the auto-generated block at the bottom.

check Check

Both stanzas hold your numbers, not the LDO config's generic starting values.

What you're looking at

PID constants are the three numbers that hold a heater steady at a target. They were measured in Ch 13, and they belong to the temperature they were measured at, so changing your bed target means re-running the tune.

Ch 13 owns the tuning procedure

bed at 100 °C, hotend at 245 °C with the part fan at 25 %. Re-run it only if you have moved a target since, for example re-tuning the bed at TARGET=110 for ASA; PID is most accurate near the temperature it was tuned at.

Caution

Do not re-run the hotend tune at the 260 °C print temperature. PID_CALIBRATE switches the heater off only at the target, and [extruder] max_temp is 270, so a 60 W Revo HF can overshoot and shut Klipper down mid-tune (verify on bench). To tune at the print temperature, raise max_temp to 290 first, under the core's rated 300 °C, then set it back.

tip Tip

the generic values are 58.437 / 2.347 / 363.769 for the bed and 26.213 / 1.304 / 131.721 for the hotend. Do not add pwm_cycle_time; Klipper's 0.100 s default is correct here.

Source: Voron startup wizard § PID tune bed & hotend · leviathan-printer-rev-d-sbv2.cfg · E3D Revo 60 W heatercore / 104NT thermistor