Ch 00a › The two rituals, and the bad day12 / 12

Step 00a.12 — Decide now what you do when it smokes, trips or bites

Step 12 of 12 · Chapter 00a — Mains safety: read before Chapter 09

(no image — see text)

Parts: none.

Do: Agree these five responses before you need one. Every fix below is the branch an existing step already owns; none of them is improvised here.

Check

All five responses agreed out loud, the breaker labelled, and the extinguisher in reach of the machine rather than in a cupboard.

What you're looking at

No parts: five agreed responses. Each row's Do this first removes energy from the machine; the Then column points at the existing step that owns the diagnosis, so nothing here is improvised.

What happens Do this first Then
Breaker or RCD trips the moment you switch on Switch off at the wall, unplug, leave it off RCD tripping is an L-or-N-to-earth fault; a breaker is L-to-N. Redo 10.18–10.19
Smoke, a hot smell, buzzing or click-cycling Switch off at the wall, not the rocker, and unplug Do not open the bay until 10.73 reads 0 V held ten seconds. Suspect a strand outside a terminal, or the PSU selector (10.2, 10.22)
A temperature climbs with nothing commanded Cut power at the switch Ch 13's what-if table calls this a heater energised through a wiring fault — back to Ch 10, do not "just watch it"
SSR reads short LOAD 1 → LOAD 2 unpowered Do not energise the machine A solid-state relay that reads short is dead and the bed would be permanently live. Replace it (10.21, 10.78)
Someone is shocked or stuck to the machine Do not touch them. Kill the circuit at the breaker you labelled in 00a.5 Then emergency services. Any shock, however small, ends the session — the machine stays unplugged until the PE sweep at 10.77 has been redone

Two standing rules on top of the table. Never re-energise a circuit that tripped without finding out why — a second trip is not new information and it is not a test. And keep the extinguisher from Step 13.1 permanently by the machine, not just on startup day: RepRap's position on unattended printing is that "No printer shall remain unattended", and this one runs multi-hour ASA prints in a hot chamber. No Voron or LDO source specifies an extinguisher class. Buy an ABC extinguisher: A covers burning plastic, C covers live electrical equipment (NFPA 10 classes). Check the label shows the C before it goes by the machine.

Good stopping point · ~25 min since the last one

the chapter is read and nothing is half-done, because nothing was started. The only durable outputs are the posted room rule, the labelled breaker, a tested meter and five agreed responses. Do not carry on into Ch 09 in the same session if you are tired; Ch 09 ends with the machine on its back and the bay open.

Source: RepRap — Safety · Ch 13 — What if · Ch 10 Steps 10.19, 10.21, 10.73